ABB CI840A 3BSE041882R1 PR:D 2x With ABB TU847 3BSE022462R1 PR:B Base
|
||
Mfr. Part Number: |
ABB CI840A 3BSE041882R1 |
Manufacturer: |
ABB |
Description: |
ABB CI840A 3BSE041882R1 |
Full Description: |
·
ABB CI840A 3BSE041882R1:- ·
For redundant communication
interface two CI840A, and one TU847 or one TU846 must be ordered. ·
S800 I/O is a comprehensive,
distributed and modular process I/O system that communicates with parent
controllers and PLCs over industry-standard field buses. ·
The CI840 Fieldbus Communication
Interface (FCI) module is a configurable communication interface that
performs operations such as signal processing, gathering of various
supervision information, OSP handling, Hot Configuration In Run, HART
pass-through and configuration of I/O modules. ·
CI840 is designed for redundant
applications. ·
The FCI connects to the
controller by way of the PROFIBUS-DPV1 fieldbus. ·
Module termination units to
use, TU846 with redundant I/O and TU847 with non-redundant I/O. ·
24 V consumption typ.:- 190 mA ·
Electrical Safety :- EN
61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201 ·
Temperature, Operating :- 0
to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C ·
Temperature, Storage :- -40
to +70 °C (-40 to +158 °F) ·
Relative humidity:- 5 to
95 %, non-condensing ·
Max ambient temperature :-
55 °C (131 °F), for vertical mounting 40 °C (104 °F) ·
Protection class :- IP20 ·
ABB TU847 3BSE022462R1:- ·
For 1+1 CI840 Supporting
non-redundant I/O. Vertical mounting of modules. Supporting non-redundant
I/O. Including: ·
The TU847 is a module termination
unit (MTU) for redundant configuration of the field communication interface
CI840/CI840A. ·
The MTU is a passive unit having connections
for power supply, electrical ModuleBus, two CI840/CI840A and two rotary
switches for station address (0 to 99) settings. ·
A ModuleBus Optical Port TB842
can be connected to TU847 via TB806. ·
Power input:- 24 V d.c.
(19.2 - 30 V) ·
Type:- Redundant
CI840/CI840A, Single I/O ·
Mounting:- Vertical or
Horizontal ·
ModuleBus current distribution:-
Maximum 5 V 1.5 A, Maximum 24 V 1.5 A ·
Acceptable wire sizes :- 0.25
- 2.5mm², 24 - 14 AWG ·
Rated insulation voltage
:- 50V ·
Dialectic test voltage :-
500 V ac ·
Temperature, Operating :- 0
to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C ·
Temperature, Storage :- -40
to +70 °C (-40 to +158° F) ·
Relative humidity :- 5 to
95 %, non-condensing ·
Max ambient temperature :-
55 °C (131 °F), for vertical mounting 40 °C (104 °F) ·
Electrical Safety :- EN
61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201 ·
Ingress protection :- IP20 |
|
|