ABB AL16-30-10 + ABB S202P + ABB S803N + Rittal SK3110
|
||
Mfr. Part Number: |
AL16-30-10 + ABB S202P + ABB S803N + Rittal SK3110 |
Manufacturer: |
ABB |
Description: |
AL16-30-10 + ABB S202P + ABB S803N + Rittal SK3110 |
Full Description: |
·
ABB AL16-30-10 :- ·
AL16 contactors are mainly used
for controlling 3-phase motors and generally for controlling power circuits
up to 690 V AC or 220 V DC. ·
The contactors can also be used
for many other applications such as isolation, capacitor switching, lighting.
·
The AL... series 1-stack 3-pole
contactors are of the block type design. - Main poles and auxiliary contact
blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted
add-on auxiliary contact blocks - Control circuit: DC operated with solid
core magnet circuit. ·
The polarity on the coil terminals (A1+ and
A2-) must be respected - Accessories: a wide range of accessories is
available. ·
AL... contactors are fitted
with low consumption DC coils and are suitable for a direct control by PLC
outputs. ·
AL16-30-10 125 V DC Contactor ·
Rated Operational Voltage:-
Auxiliary Circuit 690 V ·
Rated Frequency (f):- Auxiliary
Circuit 50 / 60 Hz ·
Max
Mechanical Switching Frequency:- 3600 cycles per hour ·
Max
Electrical Switching Frequency:- AC-1 600 cycles per hour,
AC-2 / AC-4 300 cycles per hour, AC-3 1200 cycles per hour ·
Rated
Operational Voltage :- Auxiliary Circuit 690
volt, Main Circuit 690 volt ·
Conventional
Free-air Thermal Current (Ith):- acc. to IEC
60947-5-1, q = 40 °C 16 ampere, acc. to IEC 60947-4-1, Open Contactors q = 40
°C 30 ampere ·
Rated
Operational Power AC-3 (Pe) :- (220 / 230 / 240 V) 4
KWT, (380 / 400 V) 7.5 KWT, (415 V) 9 KWT, (440 V) 9 KWT, (500 V) 9 KWT, (690
V) 9 KWT ·
Rated
Operational Current DC-13 (Ie) :- (125 V) 1.1 / 138
ampere, (24 V) 6 / 144 ampere, (250 V) 0.55 / 138 ampere, (48 V) 2.8 / 134
ampere, (72 V) 2 / 144 ampere ·
Rated
Operational Current AC-3 (Ie) :- (220 / 230 / 240 V)
55 °C 17 ampere, (380 / 400 V) 55 °C 17 ampere, (415 V) 55 °C 17 ampere, (440
V) 55 °C 16 ampere, (500 V) 55 °C 14 ampere, (690 V) 55 °C 10 ampere ·
Rated
Operational Current AC-15 (Ie) :- (220 / 240 V) 4
ampere, (24 / 127 V) 6 ampere, (380 / 440 V) 3 ampere, (500 V) 2 ampere, (690
V) 2 ampere ·
Rated
Operational Current AC-1 (Ie) :- (690 V) 40 °C 30
ampere, (690 V) 55 °C 27 ampere, (690 V) 70 °C 23 ampere ·
Rated
Frequency Limits :- 25 ... 400 hertz ·
Ambient
Air Temperature :- Close to Contactor for Storage
-60 ... +80 degree Celsius, Close to Contactor without Thermal O/L Relay
(0.85 ... 1.1 Uc) -40 ... +55 degree Celsius, Close to Contactor Fitted with
Thermal O/L Relay -25 ... +55 degree Celsius, Close to Contactor without T ·
Rated
Insulation Voltage (Ui) :- acc. to UL/CSA 600
volt, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 volt ·
ABB S202P :- ·
System pro M compact S200P
miniature circuit breakers are current limiting. ·
They have two different
tripping mechanisms, the delayed thermal tripping mechanism for overload
protection and the electromechanic tripping mechanism for short circuit
protection. ·
They are available in different
characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking
capacities (up to 25 kA at 230/400 V AC) and rated currents (up to 63A). ·
All MCBs of the product range
S200P comply with IEC/EN 60898-1, IEC/EN 609 47-2, UL1077 and CSA 22.2 No.
235, allowing the use for residential, commercial and industrial
applications. Bottom-fitting auxiliary contact can be mounted on S200P to
save 50% space.S202P-C16 Miniature Circuit Breaker - 2P - C - 16 A ·
Ambient
Air Temperature Operation -25 ... +55 °C ·
Ambient
Air Temperature Storage -40 ... +70 °C ·
Environmental
Conditions: 28 cycles with
55 °C / 90-96 % ·
Rated
Frequency (f):- 50 / 60 Hz ·
Degree
of Protection: - IP20 ·
Electrical
Endurance:- 20000 AC cycle ·
Tightening
Torque:- 2.8 N·m ·
ABB S803N :- ·
S803N-C16 High Performance MCB ·
The S803N-C16 is a 3-pole High
Performance Circuit breaker with C-characteristic, with cage terminal and a
rated current of 16 A. ·
It is a current limiting device
with a maximum breaking capacity of 36kA at 240/415V. ·
It can be used for voltages up
to 400/690V and in DC as well. ·
It has two different tripping mechanisms,
the thermal tripping mechanism for overload protection and the
electromechanic tripping mechanism for short circuit protection. The
S803N-C16 complies with IEC/EN 60898-1 and IEC/EN 60947-2 and allows the use
for residential, commercial and industrial applications. ·
It has numerous of approvals, therefore it
can be used worldwide. ·
The extensive range of
accessory makes the use of S803N-C16 more comfortable. Due to the fast arc
extinction of S803N-C16 your application will be secured. ·
Operational Voltage:- Maximum
230/400 V AC ·
Ambient Air Temperature Operation:- -25 ... +60 °C ·
Storage -40 ... +70 °C ·
Number of Poles:- 3 ·
Rated Current (In):- 125 A ·
Rated Operational Voltage:- 400/690 V AC 375 V DC ·
Rated Frequency (f):- 50 / 60 Hz ·
Rated
Insulation Voltage (Ui):- 690 V AC ·
Degree of Protection:-
IP20 ·
Rittal SK3110 :- ·
Time-saving connection technique using a terminal
strip with a screw connection from the outside. ·
Flexible
mounting on a vertical or horizontal 35 mm support rail to EN 50 022, and
snap fastening in the enclosure section or on the mounting plate using the
supplied adaptor ·
Rated operating voltage :-
24-230 V, 1~/24-60 V DC ·
Temperature setting range
:- 5-60 °C 41
°F...140 °F ·
Mounting :- DIN-rail 35 mm
, Snap-on mounting ·
Maximum Temperature :- +55
°C ·
Minimum Temperature :- +5
°C ·
Temperature Range :- +5 →
+55 °C |
Condition: |
Used / Working |
Price: |
Sales.plcadvance@gmail.com |